ELECTRICAL CABLE

ELECTRICAL CABLE

Copper Conductor Low Voltage Power and Installation Cables

Aluminium Conductor Low Voltage Power and Installation Cables

Telecom and Special Design Cables

PVC Isolated Power Cables 0,6 / 1 kV

PVC Isolated Installation Cables

XLPE Isolated Power Cables 0,6 / 1 kV

PVC Isolated Sectoral Conductor Power Cables 0,6 / 1 kV

Halogen-fre...

ELECTRICAL CABLE

Copper Conductor Low Voltage Power and Installation Cables

Aluminium Conductor Low Voltage Power and Installation Cables

Telecom and Special Design Cables

PVC Isolated Power Cables 0,6 / 1 kV

PVC Isolated Installation Cables

XLPE Isolated Power Cables 0,6 / 1 kV

PVC Isolated Sectoral Conductor Power Cables 0,6 / 1 kV

Halogen-free Power Cables 0,6 / 1 kV

XLPE Isolated Sectoral Conductor Power Cables 0,6 / 1 kV

Halogen-free Installation Cables

More

ELECTRICAL CABLE There are no products in this category.

Subcategories

  • LOW VOLTAGE COPPER...

    Low voltage copper conductor power cables

    NYY: Distribution and signal power cable for static outdoor application (with protection against direct UV-irradiation), in ground, in water, within facilities, in cable canals, in concrete, in conditions where heavier mechanical loads and specially tensile strains, are not expected. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants, same as for connection of signalling devices in industry, traffic and similar.

    N2XY: Distribution and signal power cable for static application in ground, in water, within facilities, in cable canals, in concrete, where heavier mechanical stresses are not expected, and the cable has to be protected against mechanical damages, also in conditions where cables are not exposed to heavier tensile strains. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and in other electric plants where heavier current and thermal loads are expected (operating temperature of conductor up to 90 °C).

    N2XH: Power cable suitable for fixed installation in dry and damp environment, on or under plaster, on cable trays, same as in walls and concrete. Not intended for direct laying in ground or water. For outdoor application can be laid in tubes, but in that case should be taken all precautionary measures necessary to prevent water penetration into the tubes. Suitable for supply systems in an emergency. Appropriate for application in all situations where people and material goods need to be protected in case of fire. Recommended for public buildings frequented by a lot of people, and for buildings of high material value, for industrial complexes, electric power plants, transformer stations, municipal facilities, hotels, shopping malls, hospitals, schools, airports, underground railways and similar. 

    FG7OR: Suitable for the supply and transport of commands and/or signals in industry, construction sites, in housing. For use outdoor and indoor. For installation in brickwork, metal structures, gangways, pipes, ducts or similar closed systems. Allowed for underground laying also unprotected.

    FG16OR16: Cable suitable for energy supply in industry, building sites and construction industry. For fixed wiring indoors and outdoors, even wet; for direct and indirect underground wiring. Suitable for installation at open air, on walls, metal structures, cable trays, pipes, wiring holders and similar devices. Suitable for bundle installations in environments at risk of fire.

  • LOW VOLTAGE ALUMINIUM...

    LOW VOLTAGE ALUMINIUM CONDUCTOR POWER CABLES

    NAYY: Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not be expected.

    NA2XY: Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry and distribution boards as well as in subscriber networks, where mechanical damages are not be expected.

    NA2XH: Halogen-free power cables for energy with enhanced characteristics in case of fire are used for applications where harm to human life and damage to property must be prevented in the event of fire, e. g. in power stations, industrial installations, communal establishments, hotels, airports, underground stations, railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed installation in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.

  • SINGLE CORE ELECTRICAL...

    SINGLE CORE ELECTRICAL APPLIANCE CABLES

    H05V-U / H07V-U: For internal wiring of switching boxes and other electrical appliances. For installation in closed conduits and pipes. Not for direct installation under plaster.

    H05V2-U / H07V2-U: Suitable for installations inside lighting devices, in which the max. conductor temperature under normal usage conditions does not exceed 90°C. Installation permitted in aboveground or built-in pipes if used for signalling and control circuits only. Contact with water is not permitted.

    H05Z1-U / H07Z1-U: For internal wiring of appliances as well as installation in an electrical conduit pipe either on or underneath plaster, especially for applications that require minor release of smoke or corrosive gases in the event of fire.

    H07V-R: For laying in pipes on top of or under plaster and in closed installation ducts and for internal wiring of machinery, switchgear and distributor systems. The cable is not suitable for direct laying under plaster.

    H07V2-R: Suitable for installations in aboveground or built-in pipes or similar closed systems, in which the max. conductor temperature under normal usage conditions does not exceed 90°C. If installed in supply systems, the max. continuous operating temperature has to be 70°C. For fixed and protected installations in lighting and control devices, rated voltages up to 1000 V in AC or up to 750 V in DC landward are permitted. Contact with water is not permitted.

    H07Z1-R: For internal wiring of appliances as well as installation in an electrical conduit pipe either on or underneath plaster, especially for applications that require minor release of smoke or corrosive gases in the event of fire.

    H05V-K / H07V-K: For internal wiring of switching boxes and other electrical appliances. For installation in closed conduits and pipes. Not for direct installation under plaster.

    H05V2-K / H07V2-K: Suitable for installations inside lighting devices, in which the max. conductor temperature under normal usage conditions does not exceed 90°C. Installation permitted in aboveground or built-in pipes if used for signalling and control circuits only. Contact with water is not permitted.

    H05Z1-K / H07Z1-K: For internal wiring of appliances as well as installation in an electrical conduit pipe either on or underneath plaster.

  • MULTI CORE ELECTRICAL...

    MULTI CORE ELECTRICAL APPLIANCE CABLES

    H03VV-F / H05VV-F: For internal wiring and connecting of domestic appliances involving medium mechanical load also in humid spaces.

    H03V2V2-F / H05V2V2-F: For internal wiring and connecting of domestic appliances involving medium mechanical load and high ambient temperatures also in humid spaces.

    H03VVH2-F / H05VVH2-F: For the connection of small electrical appliances (table and standard lamps, kitchen appliances, domestic vacuum cleaners, office appliances, radios etc.) at low mechanical stress in household, kitchen and office. Not for the connection of cooking and heating appliances or commercial electric tools. Not for outdoor use, in agricultural or commercial businesses.

    NYM: For installation in, on or under plaster, in dry, damp or wet rooms as well as in walls and concrete (except for shaken, jolted, tamped concrete). Also suitable for installation outdoors if protected from sunlight.

    NHXMH: Low-smoke, zero-halogen, flameretardant building wire, for installation on and under plaster in dry and wet rooms, as well as in concrete (except for shaken, jolted, tamped concrete). For indoor use only, primarily in buildings with a high concentration of people and material assets

    FROR: Suitable for connection of movable equipment or for fixed laying in areas with risk of fire. To be used in dry or wet interiors and for occasional or temporary use outdoor. Not allowed for laying undeground, even if protected.

  • UL/CSA RECOGNIZED...

    UL/CSA RECOGNIZED ELECTRICAL APPLIANCE CABLES

    UL 1015 - LiYW: Internal wiring of appliances. Tags may also indicate the following: 2,500 V peak - for electronic use only.

    UL 1028 - LiYW: Internal wiring of appliances. Tags may also indicate the following: 2,500 V peak - for electronic use only.

    UL 1569 - LiYW: Internal wiring of appliances or electronic equipment where not subjected to movement or mechanical damage. Tag may also indicate the following, “600 Volts Peak for Electronic Use Only.”

    UL 1015 - H07V2-K: Internal wiring of appliances. Tags may also indicate the following: 2,500 V peak - for electronic use only.

    UL 1569 - H05V2-K: Internal wiring of appliances or electronic equipment where not subjected to movement or mechanical damage. Tag may also indicate the following, “600 Volts Peak for Electronic Use Only.”

    UL 2464 - LiYY: Internal wiring or external interconnection of electronic equipment.

    UL 2517 - LiYY: External interconnection of electronic equipment or internal wiring of electronic equipment or appliances. Tags may also indicate the following: “600 Volts peak for Electronic Use Only”.

  • TELECOM INSTALLATION...

    TELECOM INSTALLATION CABLES

    J-YY: Suitable for telecommunications and data processing systems, for connecting public and private telephone equipment. For static installations in dry or humid environments, and on the outside walls of buildings, both on or under plaster. 

    J-HH: Suitable for telecommunications and data processing systems, for connecting public and private telephone equipment. For static installations in dry or humid environments, and on the outside walls of buildings, both on or under plaster.

    J-Y(St)Y: Suitable for telecommunications and data processing systems, for connecting public and private telephone equipment. For static installations in dry or humid environments, and on the outside walls of buildings, both on or under plaster. The screen offers protection from electromagnetic interference. Can be used in static installations down to -20°C.

    J-H(St)H: Suitable for telecommunications and data processing systems, for connecting public and private telephone equipment. For static installations in dry or humid environments, and on the outside walls of buildings, both on or under plaster. The screen offers protection from electromagnetic interference. Can be used in static installations down to -20°C.

  • CONTROL CABLES

    CONTROL CABLES

    YSLY: Flexible signal cable used for surveillance and control of static or mobile devices in industry, electric plants or offices. Lightweight and relatively thin, resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strain. Installed in dry or damp premises, outdoor application only under protection against UV-irradiation. Not intended for laying in ground or water.

    YSLYCY: Flexible signal cable used for surveillance and control of static or mobile devices in industry, electric plants or offices. Lightweight and relatively thin, resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strain. Installed in dry or damp premises, outdoor application only under protection against UV-irradiation. Not intended for laying in ground or water.

    H05VV5-F: Flexible signal cable used for surveillance and control of static or mobile devices in industry, electric plants or offices. Lightweight and relatively thin, resistant to oil and medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strain. Installed in dry or damp premises, outdoor application only under protection against UV-irradiation. Not intended for laying in ground or water.

    H05VVC4V5-K: Flexible signal cable used for surveillance and control of static or mobile devices in industry, electric plants or offices. Lightweight and relatively thin, resistant to medium mechanical loads, used for fixed or limitedly mobile installations (not permanently mobile) without strain. Installed in dry or damp premises, outdoor application only under protection against UV-irradiation. Not intended for laying in ground or water.

    HSLH: Halogen-free signal cable with improved properties under fire, suitable for different applications in control and measuring circuits, in industry and facilities where human lives or valuable property need to be protected against damages caused by fire. Suitable for fixed, same as for mobile installation, but free of mechanical stress; for dry and damp environment, not for outdoor application. Resistant to majority of most frequently used oils. 

    HSLHCH: Halogen-free signal cable with improved properties under fire, suitable for different applications in control and measuring circuits, in industry and facilities where human lives or valuable property need to be protected against damages caused by fire. Suitable for fixed, same as for mobile installation, but free of mechanical stress; for dry and damp environment, not for outdoor application. Resistant to majority of most frequently used oils.

  • ELECTRONIC CABLES

    ELECTRONIC CABLES

    LiYY: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility and small outside diameter characterise this cable.

    LiYCY: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility and small outside diameter characterise this cable.

    LiY(St)Y: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility, small outside diameter and good electromagnetic interference characterise this cable.

    LiY(St)CY: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility, small outside diameter and good electromagnetic interference characterise this cable.

    LiHH: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility, small outside diameter and halogen free structure characterise this cable.

    LiHCH: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility, small outside diameter and halogen free structure characterise this cable.

    LiH(St)H: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility, small outside diameter and good electromagnetic interference, halogen free structure characterise this cable.

    LiH(St)CH: General use of electronics, measuring-, signal, control-, and regulation technology as well as call plants and data processing. High flexibility, small outside diameter and good electromagnetic interference, halogen free structure characterise this cable.

  • LAN DATA CABLES

    LAN DATA CABLES

    CAT 5e U/UTP: For transmission of analog and digital signals up to 100mbit per second speed in data communication systems. Ethernet and LAN systems.

    CAT 5e U/UTP HFFR: For transmission of analog and digital signals up to 100mbit per second speed in data communication systems. Ethernet and LAN systems.

    CAT 6 U/UTP: For transmission of analog and digital signals up to 1 gbit per second speed in data communication systems. Ethernet and LAN systems.

    CAT 6 U/UTP HFFR: For transmission of analog and digital signals up to 100mbit per second speed in data communication systems. Ethernet and LAN systems.

  • COAXIAL CABLES

    COAXIAL CABLES

    RG6 U4: Distribution cable for indoor CATV-CCTV systems as connection cable for satellite systems where low attenuation is required.

    RG6 U6: Distribution cable for indoor CATV-CCTV systems as connection cable for satellite systems where low attenuation is required.

    RG11 U4: Distribution cable for indoor CATV-CCTV systems as connection cable for satellite systems where low attenuation is required.

    RG11 U6: Distribution cable for indoor CATV-CCTV systems as connection cable for satellite systems where low attenuation is required.

    RG59 U4: Distribution cable for indoor CATV-CCTV systems as connection cable for satellite systems where low attenuation is required.

    RG59 U6: Distribution cable for indoor CATV-CCTV systems as connection cable for satellite systems where low attenuation is required.

  • AUTOMOTIVE CABLES

    AUTOMOTIVE CABLES

    FLRY: Used in internal wiring of vehicle electrical systems.

    FLRYW: Used in internal wiring of vehicle electrical systems.

    FLYY: Used in internal wiring of vehicle electrical systems.

    FLRY11Y: Used in connection cable between truck, tractor and trailer or semi-trailer, lighting and wiring systems. For Class A usage.