SINGLE CORE ELECTRICAL APPLIANCE CABLES

SINGLE CORE ELECTRICAL APPLIANCE CABLES

H05V-U / H07V-U: For internal wiring of switching boxes and other electrical appliances. For installation in closed conduits and pipes. Not for direct installation under plaster.

H05V2-U / H07V2-U: Suitable for installations inside lighting devices, in which the max. conductor temperature under normal usag...

SINGLE CORE ELECTRICAL APPLIANCE CABLES

H05V-U / H07V-U: For internal wiring of switching boxes and other electrical appliances. For installation in closed conduits and pipes. Not for direct installation under plaster.

H05V2-U / H07V2-U: Suitable for installations inside lighting devices, in which the max. conductor temperature under normal usage conditions does not exceed 90°C. Installation permitted in aboveground or built-in pipes if used for signalling and control circuits only. Contact with water is not permitted.

H05Z1-U / H07Z1-U: For internal wiring of appliances as well as installation in an electrical conduit pipe either on or underneath plaster, especially for applications that require minor release of smoke or corrosive gases in the event of fire.

H07V-R: For laying in pipes on top of or under plaster and in closed installation ducts and for internal wiring of machinery, switchgear and distributor systems. The cable is not suitable for direct laying under plaster.

H07V2-R: Suitable for installations in aboveground or built-in pipes or similar closed systems, in which the max. conductor temperature under normal usage conditions does not exceed 90°C. If installed in supply systems, the max. continuous operating temperature has to be 70°C. For fixed and protected installations in lighting and control devices, rated voltages up to 1000 V in AC or up to 750 V in DC landward are permitted. Contact with water is not permitted.

H07Z1-R: For internal wiring of appliances as well as installation in an electrical conduit pipe either on or underneath plaster, especially for applications that require minor release of smoke or corrosive gases in the event of fire.

H05V-K / H07V-K: For internal wiring of switching boxes and other electrical appliances. For installation in closed conduits and pipes. Not for direct installation under plaster.

H05V2-K / H07V2-K: Suitable for installations inside lighting devices, in which the max. conductor temperature under normal usage conditions does not exceed 90°C. Installation permitted in aboveground or built-in pipes if used for signalling and control circuits only. Contact with water is not permitted.

H05Z1-K / H07Z1-K: For internal wiring of appliances as well as installation in an electrical conduit pipe either on or underneath plaster.

More

SINGLE CORE ELECTRICAL APPLIANCE CABLES There are 2 products.

Subcategories

Showing 1 - 2 of 2 items
Showing 1 - 2 of 2 items